Examine by gas chromatography (2.2.28), using 3-cyclohexylpropionic acid R as the internal standard.
Internal standard solution Dissolve 100 mg of 3-cyclohexylpropionic acid R in cyclohexane R and dilute to 100 mL with the same solvent.
Test solution To 0.300 g of the substance to be examined, add 4.0 mL of a 33 per cent V/V solution of hydrochloric acid R. Shake vigorously for 1 min with 1.0 mL of the internal standard solution. Allow the phases to separate (if necessary, centrifuge for a better separation). Use the upper layer.
Reference solution Dissolve 75.0 mg of 2-ethylhexanoic acid R in the internal standard solution and dilute to 50.0 mL with the same solution. To 1.0 mL of the solution add 4.0 mL of a 33 per cent V/V solution of hydrochloric acid R. Shake vigorously for 1 min. Allow the phases to separate (if necessary, centrifuge for a better separation). Use the upper layer.
The chromatographic procedure may be carried out using:
- — a wide-bore fused-silica column 10 m long and 0.53 mm in internal diameter coated with macrogol 20 000 2-nitroterephthalate R (film thickness 1.0 µm),
- — helium for chromatography R as the carrier gas at a flow rate of 10 mL/min,
- — a flame-ionisation detector,
with the following temperature programme:
Inject 1 µL of the test solution and 1 µL of the reference solution.
The test is not valid unless the resolution between the peaks corresponding to 2-ethylhexanoic acid (first peak) and the internal standard is at least 2.0.
Calculate the percentage content of 2-ethylhexanoic acid from the expression:
AT |
= |
area of the peak corresponding to 2-ethylhexanoic acid in the chromatogram obtained with the test solution, |
AR |
= |
area of the peak corresponding to 2-ethylhexanoic acid in the chromatogram obtained with the reference solution, |
IT |
= |
area of the peak corresponding to the internal standard in the chromatogram obtained with the test solution, |
IR |
= |
area of the peak corresponding to the internal standard in the chromatogram obtained with the reference solution, |
mT |
= |
mass of the substance to be examined in the test solution, in grams, |
mR |
= |
mass of 2-ethylhexanoic acid in the reference solution, in grams. |