Stavudine
Thymidine, 2¢,3¢-didehydro-3¢-deoxy-. 1-(2,3-Dideoxy--d-glycero-pent-2-enofuranosyl)thymine [3056-17-5]. » Stavudine contains not less than 98.0 percent and not more than 102.0 percent of C10H12N2O4, calculated on an anhydrous and solvent-free basis.
Packaging and storage
Preserve in tight containers, protected from light and humidity. Store at 25, excursions permitted between 15 and 30.
Identification
B:
The retention time of the major peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
Specific rotation 781:
between 45 and 40, calculated on the anhydrous basis, determined in a solution in water containing 10 mg per mL.
Water, Method 1 921:
not more than 0.5%.
Residue on ignition 281:
not more than 0.3%.
Heavy metals, Method I 231:
0.002%.
Related compounds
[noteAll testing solutions must be prepared immediately prior to use and remain refrigerated until use.]
0.01 M Ammonium acetate
Prepare as directed in the Assay.
Solution A
Prepare a filtered and degassed mixture of 0.01 M Ammonium acetate and acetonitrile (96.5:3.5).
Solution B
Prepare a filtered and degassed mixture of 0.01 M Ammonium acetate and acetonitrile (75:25).
Mobile phase
Use variable mixtures of Solution A and Solution B as directed for Chromatographic system. Make adjustments if necessary (see System Suitability under Chromatography 621).
System suitability solution
Prepare a 0.50 mg per mL solution of USP Stavudine System Suitability Mixture RS in water.
Test solution
Prepare a solution of Stavudine, accurately weighed, in water, and having a concentration of about 0.5 mg per mL.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. The flow rate is about 2.1 mL per minute. The chromatograph is programmed as follows.
Procedure
Inject equal volumes (about 10 µL) of the System suitability solution and the Test solution into the chromatograph, record the chromatograms for twice the retention time of the major peak, or at least until the last impurity has eluted, and measure the area of the responses for all the peaks. Determine the percentage of thymine in the portion of Stavudine taken by the formula:
(100)(F)(rU / rs)
in which F is the relative response factor and is equal to 0.69; rU is the peak response of thymine obtained from the Test solution; and rs is the sum of the responses of all the related peaks in the chromatogram of the Test solution, including that of the main stavudine peak: not more than 0.5% of thymine is found. Calculate the percentage of all other impurities in the portion of Stavudine taken by the formula:
100(rU / rs)
in which rU is the peak area response of each impurity obtained from the Test solution; and rs is the sum of the area responses of all the related peaks in the chromatogram of the Test solution, including that of the main stavudine peak and disregarding any peak observed in the blank: not more than 0.1% of any impurity is found; and not more than 1.0% of total impurities is found, including thymine. The quantitation limit is 0.03% of the total sample related peak areas.
Assay
[noteAll testing solutions must be prepared immediately prior to use and remain refrigerated until use.]
0.01 M Ammonium acetate
Dissolve 0.77 g of ammonium acetate in about 900 mL of water in a 1000-mL volumetric flask. Dilute with water to volume, and mix.
Mobile phase
Prepare a filtered and degassed mixture of 0.01 M Ammonium acetate and acetonitrile (95:5).
Standard preparation
Transfer about 10 mg of USP Stavudine RS, accurately weighed, to a 100-mL volumetric flask, and dissolve in and dilute with water to volume. Pipet 10.0 mL of this solution into a 50-mL volumetric flask, dilute with water to volume, and mix.
Assay preparation
Transfer about 10 mg of the Stavudine to a 100-mL volumetric flask, dissolve in and dilute with water to volume, and mix. Pipet 10.0 mL of this solution into a 50-mL volumetric flask, dilute with water to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 4.6-mm × 3.3-cm column that contains 3-µm packing L1. The flow rate is about 0.7 mL per minute. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the retention time of the stavudine peak is between 2.8 and 5.0 minutes; the column efficiency is not less than 800 theoretical plates; the tailing factor is less than or equal to 1.6; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 25 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C10H12N2O4 in the portion of Stavudine taken by the formula:
500C(rU / rS)
in which C is the concentration, in mg per mL, of USP Stavudine RS in the Standard preparation; and rU and rS are the peak responses obtained from the Assay preparation and the Standard preparation, respectively.