Benztropine Mesylate Tablets
» Benztropine Mesylate Tablets contain not less than 90.0 percent and not more than 110.0 percent of the labeled amount of C21H25NO·CH4O3S.
Packaging and storage
Preserve in well-closed containers.
Identification
Dissolve about 10 mg of USP Benztropine Mesylate RS in 50 mL of water in a separator to obtain a solution containing about 0.2 mg per mL. Transfer a portion of finely powdered Tablets, equivalent to about 10 mg of benztropine mesylate, to a suitable flask, add 50 mL of water, shake by mechanical means for 30 minutes, and filter into a second separator. Proceed as directed in the Identification test under Benztropine Mesylate Injection, beginning with Separately add 2 mL of 1 N sodium hydroxide.
Dissolution 711
Medium:
0.1 N hydrochloric acid; 900 mL.
Apparatus 2:
50 rpm.
Time:
30 minutes.
Determine the amount of C21H25NO·CH4O3S dissolved by employing the following method.
Octylamine buffer
Proceed as directed in the Assay.
Mobile phase
Prepare a filtered and degassed mixture of acetonitrile and Octylamine buffer (13:7). Make adjustments if necessary (see System Suitability under Chromatography 621).
Test solution
Use a filtered portion of the solution under test from the dissolution vessel.
Standard solution
Dissolve an accurately weighed amount of USP Benztropine Mesylate RS in Dissolution Medium, and dilute quantitatively, and stepwise if necessary, with Dissolution Medium to obtain a solution having a known concentration similar to that of the Test solution.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 220-nm detector and a 4.6-mm × 25-cm column that contains packing L7. The flow rate is about 2 mL per minute. Chromatograph the Standard solution, and record the peak responses as directed for Procedure: the tailing factor is not more than 2.0; and the relative standard deviation for replicate injections is not more than 3.0%.
Procedure
Separately inject equal volumes (about 300 µL) of the Standard solution and a filtered portion of the solution under test into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C21H25NO·CH4O3S dissolved by the formula:
900C(rU / rS)
in which C is the concentration, in mg per mL, of USP Benztropine Mesylate RS in the Standard solution; and rU and rS are the peak responses obtained from the solution under test and the Standard solution, respectively.
Tolerances
Not less than 80% (Q) of the labeled amount of C21H25NO·CH4O3S is dissolved in 30 minutes.
Uniformity of dosage units 905:
meet the requirements.
Assay
Octylamine buffer
Transfer about 0.83 mL of octylamine to a 1-L volumetric flask, dilute with water to volume, mix, and adjust with phosphoric acid to a pH of 3.0.
Diluting solution
Prepare a mixture of water, isopropyl alcohol, and phosphoric acid (60:40:0.1).
Mobile phase
Prepare a filtered and degassed mixture of Octylamine buffer and acetonitrile (11:9). Make adjustments if necessary (see System Suitability under Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of USP Benztropine Mesylate RS in Diluting solution, and dilute quantitatively, and stepwise if necessary, with Diluting solution to obtain a solution having a known concentration of about 0.04 mg per mL.
Assay preparation
Weigh and finely powder not fewer than 20 Tablets. Transfer an accurately weighed portion of the powder, equivalent to about 10 mg of benztropine mesylate, to a 250-mL volumetric flask, and add 150 mL of Diluting solution. Mix by mechanical means for not less than 60 minutes, and dilute with Diluting solution to volume. Centrifuge a portion of this mixture, and filter the supernatant layer.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 259-nm detector and a 4.6-mm × 25-cm column that contains packing L7. The flow rate is about 0.7 mL per minute. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the tailing factor is not more than 4.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 50 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of benztropine mesylate (C21H25NO·CH4O3S) in the portion of Tablets taken by the formula:
250C(rU / rS)
in which C is the concentration, in mg per mL, of USP Benztropine Mesylate RS in the Standard preparation; and rU and rS are the peak responses obtained from the Assay preparation and the Standard preparation, respectively.