*** CHEMICAL IDENTIFICATION ***

RTECS NUMBER            : XJ2854000
CHEMICAL NAME           : Thiazole, 2-amino-4-(2-(5-nitro-2-furyl)vinyl)-
CAS REGISTRY NUMBER     : 16239-84-2
BEILSTEIN REFERENCE NO. : 1078405
LAST UPDATED            : 199706
DATA ITEMS CITED        : 5
MOLECULAR FORMULA       : C9-H7-N3-O3-S
MOLECULAR WEIGHT        : 237.25
WISWESSER LINE NOTATION : T5OJ BNW E1U1- ET5N CSJ BZ
COMPOUND DESCRIPTOR     : Mutagen
SYNONYMS/TRADE NAMES :
   * 2-Amino-4-(2-(5-nitro-2-furyl)vinyl)thiazole
   * 1-(2-Aminothiazolyl)-2-(5-nitro-2-furyl)ethylene
   * 2-Thiazolamine, 4-(2-(5-nitro-2-furanyl)ethenyl)-
 
                       *** HEALTH HAZARD DATA ***
 
                            ** MUTATION DATA **
 
TYPE OF TEST            : Mutation in microorganisms
TEST SYSTEM             : Bacteria - Salmonella typhimurium
DOSE/DURATION           : 1 nmol/plate
REFERENCE :
   FEPRA7 Federation Proceedings, Federation of American Societies for
   Experimental Biology. (Bethesda, MD)  V.1-46, 1942-87.
   Volume(issue)/page/year: 41,330,1982
 
TYPE OF TEST            : DNA repair
TEST SYSTEM             : Bacteria - Salmonella typhimurium
DOSE/DURATION           : 500 nmol/well
REFERENCE :
   CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
   Sts., Philadelphia, PA 19106)  V.1-    1941-  Volume(issue)/page/year:
   34,2266,1974
 
TYPE OF TEST            : Mutation in microorganisms
TEST SYSTEM             : Bacteria - Escherichia coli
DOSE/DURATION           : 300 nmol/well
REFERENCE :
   CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
   Sts., Philadelphia, PA 19106)  V.1-    1941-  Volume(issue)/page/year:
   34,2266,1974
 
TYPE OF TEST            : DNA repair
TEST SYSTEM             : Bacteria - Escherichia coli
DOSE/DURATION           : 500 nmol/well
REFERENCE :
   CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
   Sts., Philadelphia, PA 19106)  V.1-    1941-  Volume(issue)/page/year:
   34,2266,1974

                          *** STATUS IN U.S. ***
 
   EPA GENETOX PROGRAM 1988, Positive: Histidine reversion-Ames test

 
                            *** END OF RECORD ***